- Detector:GM tube
- Dose Rate display: 0.01 - 2000 μSv/h (1 μR/h - 200 mR/h), H*(10)
- Dose Rate Accuracy: ± (15+1.5/H+0.0025H)% (in range 0.1 μSv/h - 2000 μSv/h, where H – dose rate in μSv/h)
- Dose measurement: 0.01 - 9999 mSv (0.1 mR- 999.9 R)
- Dose Accuracy : ± 20% (in range 0.01 mSv - 9999 mSv ) (1 mR - 999.9 R)
- Energy range: 0.06 - 1.5 MeV
- Energy response relative to 0.662 MeV (137Cs) : ± 15 % (in range 0.662 - 1.5 MeV)
- Survive after momentary influence of maximum permissible gamma radiation within 5 min:
- Standards compliance: X
- Alarm type: visual, audio
- Physical Parameters:
+ Dimensions 125 x 42 x 24 mm(5 x 1 5/8x 1)
+ Weight 90 g (3.17 oz)
- Environmental Characteristics Temperature :-15 up to +60 °C (from 5 up to +140 °F) from -40 to -15 °C without indication
- Humidity: up to 80% at 35°C (95°F)
- Environmental protection : X
- Drop test: X
- Water resistant : X
- Power Batteries : 2 elements of type V357
- Battery lifetime : 12 months
- Battery discharge control: LCD indication
- Additional
- Countdown timer: X
- Display of time to critical exposure: X
- Functions : seconds, minutes, hours, date, month, year
- Calendar mode: alarm clock
- PC Communication: IRDA