GOTT GOTT-EPT-146 Electrical Protection Trainer

Modules:

- Transformer And Service Line Connection - Code 146-002

Adjustable three phase transformer ratio : 240/240 VAC 0.2A, 240/240VAC 5A

Input voltage : 380/220Vac

Output socket voltage : L1, L2, L3, N, PE

Pilot lamp: L1, L2, L3

Protection: MCB 3P 10A 6kA

- Circuit Breaker 4 Pole (Ac/Dc) - Code 146-007

Input voltage socket: L1, L2, L3, N, PE

Output voltage socket: L1, L2, L3, N, PE

Protection: ELCB 4P 25A iF 30mA (AC/DC)

- Over Under Voltage Relay - Code 146-029

Operating voltage: 415VAC

Supply variation: 0.75~1.25 x Un

Upper trip: 1.05~1.25 x Un

Lower trip: 0.75~0.95 x Un

Time Delay: 0.2 ~10 sec

- Over Under Current Relay - Code 146-030

Input voltage: 415/240 VAC

Output voltage: 415/240 VAC

Protection: Fuse 0.2A, 5A

Operating voltage: 415/240VAC

Supply variation: 85~115% of Un

Time delay (t) (from fault): 0.1 to 3 sec.

On delay (ton): 0.1 to 10 sec.

Reset time: 200ms

- Power Supply Unit - Code 146-001

Input voltage: 415/240 VAC

Output voltage: 415/240 VAC

Protection: Fuse 0.2A, 5A

- Three Phase Main Supply Unit 415vac – Code 146-031

Input voltage: 3phase 415VAC

Output voltage: 3 phase 415VAC

Protection: 20A MCB Ampere Trip

- Circuit Breaker 3 Pole 6A - Code 146-003

Input voltage socket: L1, L2, L3, N, PE

Output voltage socket: L1, L2, L3, N, PE

Protection: MCB 3P 10A 6kA

- Modular Fuse Switch - Code 146-005

Input voltage socket: L1, L2, L3, N, PE

Output voltage socket: L1, L2, L3, N, PE

Protection: Modular fuse 32A

- Fi Circuit Breaker 2 Pole Ac - Code 146-006

Input voltage socket: L, N, PE

Output voltage socket: L, N, PE

Protection: ELCB 2P 25A iF 30mA

- Transformer 220V/0-24-42-240 VAC 1A

Input voltage : 240 VAC

Output voltage : 240V, 42V , 24V 1A

Protection : MCB 1P 0.5A 6kA

- Circuit Breaker 1 Pole - Code 146-004

Input voltage socket: L, N, PE

Output voltage socket: L, N, PE

Protection: MCB 1P 10A 6kA

- Protective Earthing Socket - Code 146-010

Input voltage socket: L1, L2, L3, N,

PE Output voltage socket: L1, L2, L3, N, PE

- Insulation Tester - Code 146-009

Input voltage : 240 VAC

Display: LED Test, Reset

- Load With Fault To Frame - Code 146-011

Input voltage socket: L, N, PE 

- System Earth - Code 146-013

Earth resistance : 2Ω, 8Ω

- Contact Resistance - Code 146-015

Earth resistance : 10Ω, 470Ω, 15kΩ

- Load Extra-Low Voltage 24 Vac - Code 146-012

Input voltage: 24VAC

- Protective Earth - Code 146-014

Earth resistance : 1.5Ω, 220Ω, 470Ω, 820Ω, 1322Ω, 5kΩ

- Capacitance System - Code 146-019

Capacitance : 0.1uF/450V, 0.01uF/630V

- Insulation Resistance - Code 146-020

Insulation resistance : 15kΩ, 47kΩ, 82kΩ, 220kΩ

- Conductive Parts With Potential - Code 146-016

Conductive resistance : 1.5Ω, 10Ω

- Course Of The Earth Voltage - Code 146-017

Electric potential level : 1m.,2m., 3m., 5m., 7.5m., 10m., 20m.

- Flood Detector - Code 146-021

Level simulate: 2 Level

Relay coil: 240 VAC

- Load Floor Lamp 240 Vac - Code 146-023

Input voltage : 240 VAC

Lamp type: Incandescent

- Isolating Transformer 240/240 Vac 1a - Code 146-025

Input voltage: 240 VAC

Output voltage: 240VAC/ 1A

Voltage Ratio: 1 : 1

- Auto Transformer 0-42-240 Vac 1 A - Code 146-026

Input voltage: 240 VAC

Output voltage: 42 VAC 1A

Protection: MCB 1P 0.5A 6kA

- Extra-Low Voltage Transformer - Code 146-027

Operating voltage: 240 VAC Supply

variation: 210~240 VAC

- Phase Voltage Relay - Code 146-028

Loop resistance : 220Ω, 4.7kΩ

- Short-Circuit Current & Loop Resistance - Code 146-018

- Load With Diode - Code 146-022

Resistance: 100Ω, (series with diode)

- Ac Voltmeter - Code 162-011

Measurement Mode: AC

Voltage Ranges: 5V, 50V, 250V, 1000V

- Ac Ammeter - Code 162-012

Measurement Mode: AC

Current Ranges: 1A, 5A, 25A

- U-Link - Code 159-019

For connecting junction point

- Safety Connecting Lead - Code 237-001

4mm connecting leads

- Vertical Frame - Code 297-000

High level : DIN standard A4 with two shelves

Material: Aluminium

Side Frame: T shape

Size: 3-Layer 1450mm Length

- Experiment Manual - Code 146-035

Experiment Topics:

• Understanding the Function of Over/Under Voltage Relay 

o Under Voltage Protection 

o Over Voltage Protection 

• Protection for Over and Under current Circumstances 

o Under Current Protection o Over Current Protection 

• Protection from Unbalance Phase Situations 

o Wrong Phase Sequence Detection 

o Unbalance Voltage Detection 

• The Usage of Two Level Liquid Detector Relay 

• Insulation Testing for Electrical Safety 

• Usage of Isolation Transformer to Prevent Electric Shock 

• Protection from Pulsating DC Leakage Current 

• Fault Current Protection by Using RCCB 

• Course of Earth Voltage Due to Ground Rods

Manuals :

(1) All manuals are written in English

(2) Model Answer

(3) Teaching Manuals


Details

Datasheet


This Electrical Protection Trainer have been created for learning of Dangers caused of

touch of the electrical or electrical conductor equipment, Leakage current, Simulation of

protection of leakage current by using FI circuit breaker, Prevention of “Fault” by using

separation transformer. It’s designed as panel system with 2 level mounting frame.

There have clearly symbol on each panel by silk screen. All of connecting point via safety

connector for safety in operation.