Measuring ranges Earth resistance
0-10Ω / 0-100Ω / 0-1000Ω
Earth voltage 0-30 Vac (40-500Hz)
Accuracy Earth resistance ±3% of full scale
Earth voltage ±2.5% of full scale
Measuring system Earth resistance by constant current
inverter 820 Hz, 2mA approx.
Open circuit
indication LED will be unlit
Dimensions 163(L) × 100(W) × 50(D)mm
Weight
(battery included) Approx. 460g
Power source 1.5V (AA) × 6
Safety standards IEC 1010 CAT II 30V
Accessories
Instruction manual
Test leads (red-15m, yellow-10m,
green-5m)
Auxiliary earth spikes
Carry case
Batteries
Details
FEATURES |
● High quality Taut Band movement. ● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to five minutes when the “PUSH BUTTON SWITCH” and “TIMER ON BUTTON” are pressed together. ● This will keep test “ON” for the duration of the timer. ● Battery check function. ● Calibration performed with supplied test leads. |
|
SPECIFICATIONS |
|
|
|
Measuring ranges |
Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) |
Accuracy |
Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale |
Measuring system |
Earth resistance by constant current inverter 820 Hz, 2mA approx. |
Open circuit indication |
LED will be unlit |
Dimensions |
163(L) × 100(W) × 50(D)mm |
Weight (battery included) |
Approx. 460g |
Power source |
1.5V (AA) × 6 |
Safety standards |
IEC 1010 CAT II 30V |
|
|
|
|
|
|