Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Features
Description
he MW90010A Coherent OTDR (C-OTDR) detects faults in ultra-long optical submarine cables of up to 12,000km including multiple repeaters (EDFA). It is the ideal solution for evaluating new cables at service deployment as well as for troubleshooting in-service faults.
Specifications:
|
Item |
Specification Value |
|
Fiber under test |
ITU-T G.653 (DSF) |
|
Optical connector |
FC, SC, DIN, HSM-10/A, ST, LC |
|
Wavelength (Probe light) |
1535.03 to 1565.08 nm |
|
Wavelength accuracy |
±0.2 nm (20 - 30°C) |
|
Warm-up time |
30 minutes (20 - 30°C) |
|
Pulse width |
3/10/30/60/100 µs |
|
Optical output power |
0 to +13 dBm, 0.5 dB Steps |
|
Dynamic range (S/N=1) |
17 dB
|
|
Dead zone |
0.5 km (Pulse width: 3 µs) |
|
Distance range |
100 km, 500 km to 12,000 km (in 500 km steps) |
|
Measurement time |
15 minutes (Distance Range: 1000 km, Average times: 216) |
|
Dimensions and mass |
320 (W) x 177 (H) x 451 (D) mm, < 17 kg |