- Number of output phases: 1
AC Output
- Power: 1000VA
Voltage
- Output voltage range: 150V / 300V / Auto
- Accuracy: 0.2% + 0.2% F.S.
- Resolution: 0.1V
- Distortion:
+ 0.3% @ 50/60Hz
+ 1% @ 15–1kHz (Typical)
- Line regulation: 0.1%
- Load regulation: 0.2%
Maximum Current (per phase)
- RMS: 8A / 4A (150V / 300V)
- Peak: 48A / 24A (150V / 300V)
Frequency
- Frequency range: DC, 15 ~ 1kHz
- Accuracy: 0.15%
DC Output
- Power: 500W
- Voltage: 212V / 424V
- Current: 4A / 2A (212V / 424V)
- Programmable output impedance range: 0Ω + 200µH ~ 1Ω + 1mH
- Harmonic and interharmonic simulation bandwidth: 2400Hz
Input Specifications
- Voltage range: 1Ø 100~240V ±10% VLN
- Frequency range: 47 to 63Hz
- Current (per phase): 18A Max. @ 90V
- Power factor: 0.97 Min
Measurement
Voltage
- Voltage range: 150V / 300V
- Voltage accuracy: 0.2% + 0.2% F.S.
- Resolution: 0.1V
Current
- Range (Peak): 48A
- Current accuracy (RMS): 0.4% + 0.3% F.S.
- Current accuracy (Peak): 0.4% + 0.6% F.S.
Power
- Accuracy: 0.4% + 0.4% F.S.
- Resolution: 0.1W
- Harmonic analysis range: 2~40 orders
Other Specifications
- Communication interfaces: USB, LAN, GPIB, RS-232 (optional)
Temperature Range
- Operating: 0˚C to 40˚C
- Storage: -40˚C to 85˚C
- Safety & EMC standards: CE (including EMC & LVD)
- Dimensions (H x W x D): 133.35 x 82.6 x 569.5mm
- Weight: 20 kg