CS Instruments 0699 0090 Mobile Compressed Air Quality Tester
OIL CHECK 500
Measured medium: Compressed air, nitrogen, (free from aggressive, corrosive, acid, toxic, flammable and oxidising compo- nents).
Further gases on request
Measuring unit: Residual oil content in mg oil/norm m³ referred to 1.0 bar [abs], +20 °C, 0% relative humidity, in accordance with ISO 8573-1
Identifiable substances: Hydrocarbons, functional hydrocarbons, aromatic hydrocarbons
Field of application: After activated carbon filter, after activated carbon adsorber, after oil-free compressor, always with con- nected upstream filtration and dryer
Ambient temperature: +20 °C... +45 °C, rel. humidity <= 75% without condensation
Compressed air temperature: +20 °C... +50 °C
Operational overpressure: 3...9 bar, optional pressure reducer connected upstream for up to 300 bar
Humidity of measured gas: <= 40% rel. humidity, pressure dew point max. +10 °C, non-condensable humidity
Compressed air connection: G 1/4" female thread according to ISO 228-1
Measured values: mg/norm m³, pressure and temperature compensated residual oil vapour content
Measuring range: 0,001...5 mg/m³ (higher measuring ranges on request)
Detection limit (residual oil): 0,001 mg/m³
Flow of measuring gas: approx. 0,5 norm litres/minute, referred to to 1.0 bar [abs] and + 20 °C, (atmospheric conditions)
Plug-in power supply: 100...240 VAC/1 Ph./PE/50...60 Hz / ± 10%
Outputs:
Digital output: RS 485 interface (Modbus RTU), Ethernet via DS 400/500
Analogue output: 4...20 mA (electrically isolated)
Optional: 2x 4...20 mA analogue output (electrically isolated), 2 alarm relays for external alarm unit, alarm values freely adjustable
Operating hours counter: integrated
Dimensions (mm): 200 x 130 x 120 (W x H x D)
Weight: approx. 7 kg
PC 400
Measuring range: 0.1 μm ... 5 μm measuring channels: 0.1 ... 0.5 μm; 0.5 ... 1 μm; 1 ... 5 μm
Accuracy: 50% at 0.1 μm
100% at> 0.3 μm
Flow rate: 28.3 L / min (1 CFM)
Light source: laser diode
Interface: RS 485 (Modbus protocol)
Power supply: 24VDC, 300mA
FA510
Measuring range: -80…20 °Ctd
Accuracy:± 1°C at 50…-20 °Ctd; ± 2°C at -20…-50 °Ctd; ± 3°C at -50…-80 °Ctd
Pressure range: -1…50 bar; Special version up to 350 bar
Power supply: 24 VDC (10…36 VDC)
Protection class: IP 65
EMC: In acc. with DIN EN 61326-1
Operating temperature:-20…70 °C
Connection: M12, 5-pin
PC connection: Modbus-RTU interface (RS485)
Analogue output: 4…20 mA (3-wire)
Burden for analogue output: <500 Ω
Screw-in thread: G 1/2″; Optional: UNF 5/8", NPT 1/2"
Dimensions: Ø 30 mm, length approx. 130 mm
Choose units: % RH, °Ctd, g/m³, mg/m³, ppm V/V
Scaling: 4…20 mA change