Does your server need software to boot?

08/27/2025 09:55:43

When operating electric motors in a factory, direct starting can cause many problems: current surges, mechanical shock, equipment damage and production interruptions. The solution to overcome this situation is the soft starter circuit.

What is a soft starter circuit?

A soft starter is an electrical device that reduces the starting current and torque when the motor starts running. Instead of immediately supplying the rated voltage, the soft starter gradually increases the voltage, allowing the motor to start smoothly, limiting mechanical shock and reducing stress on the electrical system as well as mechanical equipment.

If the plant does not use a soft starter circuit

- High starting current: Direct-start motors can generate currents 6-8 times higher than the rated current, causing overload of the electrical system, easily tripping the circuit breaker or causing power outages.

- Mechanical shock, equipment damage: Sudden starting causes strong impacts on the transmission system (conveyor belt, pump, etc.), leading to slipping, misalignment of the conveyor belt or rapid damage to bearings.

- High maintenance costs: Equipment wears out quickly, requires frequent repairs, causing high costs.

- Production interruptions: Mechanical and electrical failures can cause sudden machine stops, affecting production progress.

When the factory uses soft starter circuit

- Reduce starting current: Can cut up to 60% compared to direct starting, avoiding overloading the electrical system.

- Protect the motor and mechanics: Limit impact, reduce sudden torque, prolong the life of the motor and transmission equipment.

- Save maintenance costs: Reduce wear and tear → reduce repairs → increase continuous operating time.

- Stabilize the power grid: Avoid voltage fluctuations that affect the entire system.

- Increase operating efficiency: Smooth start, low noise, ensure safety and improve production efficiency.

For example, at EMIN, ATS22C17Q Soft start circuits are often chosen by businesses thanks to their ability to reduce starting current by up to 60%, while integrating many motor protection modes.

See more in category: Soft starter

Popular types of soft starter circuits

- Depending on the type of motor and operating requirements, businesses can choose one of the following solutions:

- Impedance type soft starter circuit: Uses resistors to limit the current at startup. Suitable for light-duty motors such as pumps and fans.

- Autotransformer type soft starter circuit: Regulates voltage through a transformer, suitable for large-capacity three-phase motors that require high starting torque.

- Partial winding type soft starter circuit: Used for motors with special structures, effectively reducing starting current but more complicated to install.

- Semiconductor soft starter circuit: The most popular today, using thyristors to control voltage flexibly. The advantage is easy to program, integrating many motor protection features.

Refer to the article: What is soft starter? Practical application of starter software

Conclusion: Does your plant need a soft starter circuit?

For factories using many large capacity motors, conveyors, pumps or rotating equipment that need to start frequently, soft starter circuits are almost a mandatory choice. It helps the system operate more safely, limits damage and significantly reduces maintenance costs. 

On the contrary, small factories with lightly loaded motors and few starts may not need to invest immediately. But in the long run, soft starter circuits are still a wise investment, like insurance to help factories avoid risks and save costs when expanding production.

Related News

6 Essential Measuring Instruments in a Solar Technician’s Tool Bag
09/16/2026 14:19:49

A measurement toolkit for solar PV installers does not necessarily need to contain a large number of instruments or excessive functions. What matters is having the right tool for each task on the roof: measuring DC voltage, checking string current, verifying polarity, testing insulation, checking grounding, or commissioning the entire system.

5 Steps to Check Grounding for Rooftop Solar PV Systems During the Stormy Season
09/16/2026 11:51:17

Rooftop solar PV arrays are installed at elevated locations and contain numerous metal frames, aluminum rails, and long cable runs across the roof. As the stormy season approaches, the grounding and lightning protection systems should be inspected to ensure that fault current and lightning current can follow the intended paths.

Why Does a Soldering Iron Heat Up Quickly but Still Solder Slowly ?
09/16/2026 11:04:47

Before contacting the material, a handheld soldering iron mainly heats the soldering tip. Once soldering begins, heat is continuously transferred from the tip to the material. If the heat supply is not sufficient to compensate for heat loss, the temperature at the contact area drops and the processing time increases

Decoding the Challenges of Semiconductor Chip Testing
09/15/2026 13:57:41

In the semiconductor testing and measurement sector—where every nanosecond and microvolt can determine the success or failure of a chip design—choosing the right test equipment has never been simply a matter of comparing specifications on paper.

Causes of nylon fabric yellowing
09/15/2026 10:05:40

Nylon fabric yellowing is a surface color change in which white or light-colored material turns yellow when exposed to light, heat, or chemicals. Therefore, a fabric color fastness tester is an essential part of the quality control process, helping manufacturers evaluate color stability before discoloration occurs in finished products.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts