For full functionality of this site it is necessary to enable JavaScript.
EMIN.ASIA
0

Does your server need software to boot?

08/27/2025 09:55:43

When operating electric motors in a factory, direct starting can cause many problems: current surges, mechanical shock, equipment damage and production interruptions. The solution to overcome this situation is the soft starter circuit.

What is a soft starter circuit?

A soft starter is an electrical device that reduces the starting current and torque when the motor starts running. Instead of immediately supplying the rated voltage, the soft starter gradually increases the voltage, allowing the motor to start smoothly, limiting mechanical shock and reducing stress on the electrical system as well as mechanical equipment.

If the plant does not use a soft starter circuit

- High starting current: Direct-start motors can generate currents 6-8 times higher than the rated current, causing overload of the electrical system, easily tripping the circuit breaker or causing power outages.

- Mechanical shock, equipment damage: Sudden starting causes strong impacts on the transmission system (conveyor belt, pump, etc.), leading to slipping, misalignment of the conveyor belt or rapid damage to bearings.

- High maintenance costs: Equipment wears out quickly, requires frequent repairs, causing high costs.

- Production interruptions: Mechanical and electrical failures can cause sudden machine stops, affecting production progress.

When the factory uses soft starter circuit

- Reduce starting current: Can cut up to 60% compared to direct starting, avoiding overloading the electrical system.

- Protect the motor and mechanics: Limit impact, reduce sudden torque, prolong the life of the motor and transmission equipment.

- Save maintenance costs: Reduce wear and tear → reduce repairs → increase continuous operating time.

- Stabilize the power grid: Avoid voltage fluctuations that affect the entire system.

- Increase operating efficiency: Smooth start, low noise, ensure safety and improve production efficiency.

For example, at EMIN, ATS22C17Q Soft start circuits are often chosen by businesses thanks to their ability to reduce starting current by up to 60%, while integrating many motor protection modes.

See more in category: Soft starter

Popular types of soft starter circuits

- Depending on the type of motor and operating requirements, businesses can choose one of the following solutions:

- Impedance type soft starter circuit: Uses resistors to limit the current at startup. Suitable for light-duty motors such as pumps and fans.

- Autotransformer type soft starter circuit: Regulates voltage through a transformer, suitable for large-capacity three-phase motors that require high starting torque.

- Partial winding type soft starter circuit: Used for motors with special structures, effectively reducing starting current but more complicated to install.

- Semiconductor soft starter circuit: The most popular today, using thyristors to control voltage flexibly. The advantage is easy to program, integrating many motor protection features.

Refer to the article: What is soft starter? Practical application of starter software

Conclusion: Does your plant need a soft starter circuit?

For factories using many large capacity motors, conveyors, pumps or rotating equipment that need to start frequently, soft starter circuits are almost a mandatory choice. It helps the system operate more safely, limits damage and significantly reduces maintenance costs. 

On the contrary, small factories with lightly loaded motors and few starts may not need to invest immediately. But in the long run, soft starter circuits are still a wise investment, like insurance to help factories avoid risks and save costs when expanding production.

Related News

What is the difference between oil-lubricated vacuum pumps and oil-free diaphragm pumps?
07/17/2026 10:05:46

While both generate a vacuum, oil-lubricated pumps and oil-free diaphragm pumps differ significantly in their operating principles, advantages, and applications. Oil-lubricated pumps are typically chosen when a system requires a deep vacuum and strong suction power, whereas diaphragm pumps are preferred for laboratories, chemical processes, and environments where oil vapors must be avoided

Which Vacuum Pump Should You Choose for a Microbiology Lab to Avoid Affecting Samples?
07/15/2026 14:45:07

Vacuum pumps are utilized in a wide range of microbiology laboratory procedures, from membrane filtration and the aspiration of supernatants following centrifugation to sample concentration and the support of negative-pressure systems. Selecting the appropriate pump not only ensures more stable operational processes but also minimizes the risk of sample contamination, reduces maintenance costs, and extends the equipment's lifespan

QCVN 25:2025/BKHCN Takes Effect: Do Businesses Need to Prepare Electrical Safety Testing Equipment?
07/15/2026 09:15:04

Electrical safety is consistently one of the primary criteria evaluated before electrical or electronic equipment—or industrial components—are released to the market. A product may operate reliably yet still fail to meet requirements if its insulation lacks sufficient durability, its grounding resistance exceeds permissible limits, or leakage current occurs during operation.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts