Test voltage (dc): 250V, 500V, 1000V, 2500V, 5000V /+10 %
Range: 200 kΩ to 1 TΩ /5%
Bar graph range: 0 to 1 TΩ
Leakage current measurement: 1 nA to 2 mA /± 5 % + 2 nA
Capacitance measurement: 0.01 uF to 15.00 μF /15 % rdg + 0.03 μF
Timer: 0 to 99 minutes
Live circuit warning: 30 V to 660 V ac/dc /± 15 % + 2 V
Display: 75 mm x 105 mm
Power: 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC): harger Input (AC) 85 V to 250 V ac 50/60 HZ 20 VA
Dimensions: 170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in)
Weight: 3.6 kg (7.94 lb)
Enclosure sealing : IP40
Input overload protection: 1000 V ac
include: Set Test Cables with Alligator Clips (red, black, green), Infrared adapter with interface cable,FlukeView Forms Basic CD-ROM, AC Power Cord, English Manual, Users Manual on CD-ROM, Quick Reference Card, Software License Agreement, Registration Card, FlukeView Forms Installation Guide, USB-IR Cable Installation Guide, Set Ruggedized Alligator Clips
The tester’s accuracy is specified for one year after calibration at operating temperatures of 0 °C to 35 °C. For operating temperatures outside the range (-20 °C to 0 °C and 35 °C to 50 °C), add ± .25 % per °C, except on the 20 % bands add ± 1 % per °C.
Insulation resistance measurement |
||
|
Test voltage (dc) |
Range (dc) |
Accuracy (± reading) |
| 250 V | < 200 kΩ 200 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
unspecified 5 % 20 % unspecified |
| 500 V | 200 kΩ 200 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
unspecified 5 % 20 % unspecified |
| 1000 V | < 200 kΩ 200 kΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
unspecified 5 % 20 % unspecified |
| 2500 V | < 200 kΩ 200 kΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
unspecified 5 % 20 % unspecified |
| 5000 V | < 200 kΩ 200 kΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
unspecified 5 % 20 % unspecified |
| 10000 V (1555 only) |
< 200 kΩ 200 kΩ to 200 GΩ 10 GΩ to 2 TΩ > 2 TΩ |
unspecified 5 % 20 % unspecified |
| Bar graph range | 0 to 1 TΩ | |
| Insulation test voltage accuracy | -0 %, +10 % at 1 mA load current | |
| Induced ac mains current rejection | 2 mA maximum | |
|
Charging rate for capacitive load |
5 seconds per μF |
|
|
Discharge rate for capacitive load |
1.5 s/μF |
|
|
Leakage current measurement |
Range: 1 nA to 2 mA |
Accuracy: ± (5 % + 2 nA) |
|
Capacitance measurement |
Range: 0.01 uF to 15.00 μF |
Accuracy: ± (15 % rdg + 0.03 μF) |
|
Timer |
Range: 0 to 99 minutes |
Resolution Accuracy: |
|
Live circuit warning |
Warning Range: |
Voltage Accuracy: |
General specifications |
|
| Display | 75 mm x 105 mm |
| Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
| Charger Input (AC) | Charger Input (AC) 85 V to 250 V ac 50/60 HZ 20 VA |
| This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. | |
| Dimensions | 170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in) |
| Weight | 3.6 kg (7.94 lb) |
| Temperature (operating) | -20 ºC to 50 ºC (-4 ºF to 122 ºF) |
| Temperature (storage) | -20 ºC to 65 ºC (-4 ºF to 149 ºF) |
| Humidity | 80 % to 31 ºC decreasing linearly to 50 % at 50 ºC |
| Altitude | 2000 m |
| Enclosure sealing | IP40 |
| Input overload protection | 1000 V ac |
| Electromagnetic compatibility | EN 61326 |
| Certifications | ![]() ![]() ![]() |
| Safety compliance | CAT III 1000 V, CAT IV 600 V |
| Pollution degree | 2 |