GOLDSOL VLF-40TD High Voltage Test Set (1–40 kV AC/DC)
Power supply: 220 V ± 10% AC (110 V can be customized), 50/60 Hz, single phase.
AC output voltage: 1–40 kV peak (28.2 kV RMS).
DC output voltage: 1–40 kV.
Output frequency: 0.1 Hz, 0.05 Hz, 0.02 Hz, 0.01 Hz (automatic variable frequency).
Load capacity: Max. 1.0 μF @ 0.1 Hz; max. 10.0 μF @ 0.01 Hz.
Frequency stability: Fluctuation < 0.5%.
AC voltage measurement accuracy: ±3%.
AC voltage measurement resolution: 0.1 kV.
AC current measurement accuracy: ±3%.
AC current measurement range: 0–20 mA; resolution: 0.1 mA.
Positive and negative voltage peak error: ≤3%.
Voltage waveform distortion: ≤3%.
Construction: Integrated device.
Ambient operating conditions: Indoor and outdoor temperature: -10 °C to +50 °C.
Humidity: ≤85%.
Technical Specifications of VLF tgδ Test (Optional)
tgδ test voltage range: 1–40 kV.
Measurement voltage accuracy: 1%.
Dielectric loss test frequency: 0.1 Hz.
Measurement range: 0.01 × 10⁻³–655.35 × 10⁻³.
Dielectric loss accuracy: 1 × 10⁻⁴.
Dielectric loss resolution: 1 × 10⁻⁵.
Capacitance measurement range: 0.001–10 μF.
Capacitance measurement resolution: 0.001 μF.
Current measurement range: 0–20 mA; Tan Delta/PD test curve.
Current resolution: 0.1 mA.
Insulation resistance: 1 MΩ–65,535 MΩ (if exceeded, the device will prompt the excess).
Insulation resistance resolution: 1 MΩ.
Main Technical Specifications of VLF PD Test (Optional)
Partial discharge measurement range: 0.1 pC–10,000 pC.
Partial discharge detection resolution: 1 pC.
PD measurement accuracy: 3%.
Capacitance range: 0.001–10 μF.
Sampling bits: 12 bits.
Sampling speed: 200 MS/s; U, PD & tgδ curve.
Test voltage: 0 to rated value (40 kV).
Display of instantaneous and peak PD values.
Display of discharge inception voltage and discharge extinction voltage.
Discharge pulse frequency: 1–2,000 kHz.
Real-time output of the partial discharge evaluation report.
DC Leakage Current Measurement (Optional)
DC output rated voltage: 40 kV max.
DC voltage accuracy: 3%.
Leakage current range: 0–2,000 μA (0–20 mA can be customized).
DC current resolution: 1 μA.
DC current accuracy: 3%.
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

