Display: LCD; 7 segments, 4-digit display, backlight
LEDs: Flashlight, NCV
Voltage measurement: 1 mVAC … 1000 VAC TRMS, 1 mVDC … 1500 VDC
Overload protection - high impedance: 10 MΩ voltage measurement
Current measurement:
Clamp: 0.2 AAC … 1000 AAC TRMS, 0.01 ADC … 1000 ADC
Socket: 2 µAAC … 400 µAAC TRMS, 2 µADC … 400µADC
Resistance measurement: 0 Ω … 40 MΩ
Capacitance measurement: 10 nF … 100 µF
Continuity test: < 30 Ω acoustic signal; Reversing point 0 Ω to 30 Ω (± 20 Ω)
Diode test: 0 V … 1.0 V
Frequency measurement: 1 Hz … 9,99 MHz
Clamp opening: 35 mm, drop-shaped
Distance of measuring cables: 25 mm
TRMS: Yes
NCV (non-contact voltage measurement): Yes (AC only)
LPF (low-pass filter): Yes, 1 kHz / –3 dB
Flashlight: Yes
Automatic shutdown: Yes
Self-test: Yes
Measuring category: CAT IV / 1000 V
Pollution degree: 2
Power supply: Batteries, 2 × 1.5 V AAA, IEC LR03
Tested per: IEC 61010-1, IEC 61010-2-032
Dimensions: Approx. 255 × 81 × 43 mm
Weight: Approx. 300 g (without batteries)