pH Range: 0.00 to 14.00 pH
pH Resolution: 0.01 pH
pH Accuracy: ±0.02 pH
pH Calibration: automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
mV Range: ±600.0 mV
mV Resolution: 0.1 mV
mV Accuracy: ±0.5 mV
ORP Range: ±2000 mV
ORP Resolution: 0.1 mV
ORP Accuracy: ±1.0 mV
ORP Calibration: automatic at one custom point (relative mV)
DO Range: 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
DO Resolution: 0.1%; 0.01 ppm (mg/L)
DO Accuracy: 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading
DO Calibration: automatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L).
Atmospheric Pressure Range:450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution: 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy: ±3 mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration: automatic at one custom point
Temperature Range: -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
Temperature Resolution: 0.01 K, 0.01 °C, 0.01 °F
Temperature Accuracy: ±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration: automatic at one custom point
Temperature Compensation: automatic from -5 to 55 °C (23 to 131 °F)
Logging Memory: 45,000 records (continuous logging or log-on-demand of all parameters)
Logging Interval: one second to three hours
PC Connectivity: USB to PC with HI9298194 Hanna software installed
Battery Type/Life: 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)
Environment: 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions: 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight: 400 g (14.2 oz.)
Ordering Information: HI98196 is supplied with HI7698196 probe, HI7698194-0 pH sensor, HI7698194-2 DO sensor, 20 metter cable, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.