AC Current range: 10.00 or 100.0 A AC, 2 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), Effective value rectifier
DC Current range: 10.00 or 100.0 A AC, 2 ranges (±1.5 % rdg. ±5 dgt.)
AC Voltage range: 4.200 to 600 V AC, 4 ranges (±2.3 % rdg. ±8 dgt. at 50 or 60Hz), Effective value rectifier
DC Voltage range: 420.0 mV to 600 V DC, 5 ranges (±1.3 % rdg. ±4 dgt.)
Resistance: 420.0 to 42.00 M-ohm, 6 ranges
Accuracy: ±2.0 % rdg. ±4 dgt. (at 420 to 420 k-ohm range)
Continuity: 420.0 ohm (Buzzer sounds at approx. 50 ohm or less)
Frequency characteristics: AC current: 10 to 1 kHz, AC voltage: 30 to 500 Hz
Display Section: Digital / LCD, maximum 4199 dgt.
Sampling Rate: 2.5 times/sec
Crest Factor (RMS): 2.5 or less (150 A, 1000 V maximum)
Max. Circuit Voltage: 600 V AC rms (insulated wire)
Power Supply: CR2032 (3 VDC) × 1, Continuous use 25 hours
Core jaw dia.: Ø35 mm(1.38 in)
Dimensions: 57 mm(2.24 in)W × 180 mm(7.09 in)H × 16 mm(0.63 in)D
Weight: 170 g (6.0 oz)
Accessories: 9208 TEST LEAD (1), 9398 CARRYING CASE (1)
| AC Current range: | 10.00 or 100.0 A AC, 2 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), Effective value rectifier |
| DC Current range: | 10.00 or 100.0 A AC, 2 ranges (±1.5 % rdg. ±5 dgt.) |
| AC Voltage range: | 4.200 to 600 V AC, 4 ranges (±2.3 % rdg. ±8 dgt. at 50 or 60Hz), Effective value rectifier |
| DC Voltage range: | 420.0 mV to 600 V DC, 5 ranges (±1.3 % rdg. ±4 dgt.) |
| Resistance: | 420.0 to 42.00 M-ohm, 6 ranges |
| Accuracy: | ±2.0 % rdg. ±4 dgt. (at 420 to 420 k-ohm range) |
| Continuity: | 420.0 ohm (Buzzer sounds at approx. 50 ohm or less) |
| Analog Output: | None |
| Frequency characteristics: | AC current: 10 to 1 kHz, AC voltage: 30 to 500 Hz |
| Display Section: | Digital / LCD, maximum 4199 dgt. |
| Sampling Rate: | 2.5 times/sec |
| Crest Factor (RMS): | 2.5 or less (150 A, 1000 V maximum) |
| Max. Circuit Voltage: | 600 V AC rms (insulated wire) |
| Power Supply: | CR2032 (3 VDC) × 1, Continuous use 25 hours |
| Core jaw dia.: | Ø35 mm(1.38 in) |
| Dimensions: | 57 mm(2.24 in)W × 180 mm(7.09 in)H × 16 mm(0.63 in)D |
| Weight: | 170 g (6.0 oz) |
| Accessories: | 9208 TEST LEAD (1), 9398 CARRYING CASE (1) |
Manufacturer: Hioki - Japan
Origin: Japan
| DC Current | 10.00/ 100.0 A, Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| AC Current | 10.00/ 100.0 A, (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| DC Voltage | 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt. |
| AC Voltage | 4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to 500 Hz, True RMS) |
| Resistance | 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt. |
| Crest factor | 2.5 and under (150 A, 1000 V max.) |
| Other function | Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power save, Auto zero (DC A) |
| Display | LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s |
| Power supply | Coin type lithium battery (CR2032) ×1, Continuous use 25 hours |
| Core jaw dia. | φ 35 mm (1.38 in) |
| Dimensions, mass | 57 mm (2.24 in) W × 180 mm (7.09 in) H × 16 mm (0.63 in) D, 170 g (6.0 oz) |
| Supplied accessories | Instruction Manual ×1, TEST LEAD L9208 ×1, CARRYING CASE 9398×1 |