Technical specifications
1. The Power Source and the Voltage: AC220V±5%, 50-60 Hz
2.Time-delayed control: 0-60 seconds, adjustable
3.The Distance from the Indenter Center to the Instrument Body: 165mm
4.Overall Dimension (Length×Width×Height): 551×260×800 mm
5.The Net Weight of the Tester: 80kg (Approx)
Technical specifications
1. The Power Source and the Voltage: AC220V±5%, 50-60 Hz
2.Time-delayed control: 0-60 seconds, adjustable
3.The Distance from the Indenter Center to the Instrument Body: 165mm
4.Overall Dimension (Length×Width×Height): 551×260×800 mm
5.The Net Weight of the Tester: 80kg (Approx)
6.Specifications of Rockwell Hardness
|
Testing force(N) |
Initial Testing Force |
98.07(10kg) |
Tolerance ±2.0% |
|
|
Total testing force |
588.4(60kg) |
Tolerance ±1.0% |
||
|
980.7(100kg) |
||||
|
1471(150kg) |
||||
|
Indenter |
Diamond Cone Indenter |
|||
|
Ф1.5875mm Ball Indenter |
||||
|
Scales |
HRA |
HRB |
HRC |
HRD |
|
Max height of samples |
175mm |
|||
7.The Tolerance of Rockwell Hardness Display Value
|
Hardness Scale |
HardnessRangeof The Standard Testing Blocks |
The Max. Tolerance of Display Value |
Repeatabilitya |
|
HRA |
(20~≤75)HRA |
±2HRA |
≤0.02(100-H)or 0.8 Rockwell Unitb |
|
(>75~≤88)HRA |
±1.5HRA |
||
|
HRB |
(20~≤45)HRB |
±4HRB |
≤0.04(130-H)or 1.2 Rockwell Unitb |
|
(>45~≤80)HRB |
±3HRB |
||
|
(>80~≤100)HRB |
±2HRB |
||
|
HRC |
(20~≤70)HRC |
±1.5HRC |
≤0.02(100-H)or 0.8 Rockwell Unitb |
|
a:H is average hardness value b:Confirm as higher value |
|||
8.The Technical Specification of Brinell Hardness Tester
|
Testing force |
294.2N(30kg) |
Tolerance ±1.0% |
||
|
306.5N(31.25kg) |
||||
|
612.9N(62.5kg) |
||||
|
980.7N(100kg) |
||||
|
1839N(187.5kg) |
||||
|
Indenter |
φ2.5mm,φ5mmBall Indenter |
|||
|
Scales |
HBW1/30 |
HBW2.5/31.25 |
HBW2.5/62.5 |
|
|
HBW5/62.5 |
HBW10/100 |
HBW2.5/187.5 |
||
|
Eyepiece magnification |
15× |
|||
|
Objective |
2.5×(resolution 0.5μm),5×(resolution 0.25μm) |
|||
|
Max Height of Sample |
For 2.5×:Max Height is 95mm For 5×:Max height is 115mm |
|||
9. The Tolerance and Repetition of Displayed Value for Brinell Hardness Tester
|
Hardness Block(HBW) |
Tolerance(%) |
Repeatability (%) |
|
≤125 |
±3 |
3 |
|
125<HBW≤125 |
±2.5 |
2.5 |
|
>225 |
±2 |
2 |
10. Technical Specifications of Vickers Hardness
|
Test force |
294.2N(30kg) |
Tolerance ±1.0% |
|
980.7N(100kg) |
||
|
Indenter |
Diamond Vickers Indenter |
|
|
Scale |
HV30 |
HV100 |
|
Eyepiece magnification |
15× |
|
|
Objective magnification |
5×(Resolution 0.25μm) |
|
|
Max. Height of Specimen |
115mm |
|
11. The Tolerance and Repetition of Displayed Value for Vickers Hardness Tester
|
Tolerance of Displayed Value |
Repetition of Displayed Value |
|||
|
Hardness scale |
Value of Hardness Block |
Tolerance of Displayed Value |
Value of Hardness Block |
Repetition of Displayed Value |
|
HV30 HV100 |
≤250HV |
±3% |
≤225HV |
6% |
|
300~1000HV |
±2% |
>225HV |
4% |
|