For full functionality of this site it is necessary to enable JavaScript.

Cirrus CR161D クラス 1 騒音計 (20~140 dB, Class 1, Data Logging, 1:1 Octave Bands, NC/NR Curves)

- Applicable Standards

IEC 61672-1:2013 Class 1 

IEC 61672-1:2002 Class 1 

IEC 60651:2001 Type 1 I 

IEC 60804:2000 Type 1 

IEC 61252:1993 Personal Sound Exposure Meters

ANSI S1.4 -1983 (R2006), ANSI S1.43 - 1997 (R2007)

ANSI S1.25:1991

- Microphone: Class 1 MK:224 pre-polarized, 

- Microphone Preamplifier: MV:200 Removable Preamplifier (All versions)

- Total Measurement Range: 

20dB to 140dB RMS Single Range

Noise Floor: <18dB(A) Class 1

- Frequency Weightings : RMS & Peak : A, C, & Z Measured Simultaneously

Frequency Bands: 10 Octave Bands (31.5Hz to 16kHz, C & D variants)

- Time Weightings: Fast, Slow & Impulse Measured Simultaneously

- Display: High resolution display. Ambient light sensor & illuminated keypad

- Memory: 4GB (B, C & D Versions), 32GB factory fit option

- AuditStore:Measurement verification data stored in secure memory

- Time History Data Rates (Global settings): 10ms, 62.5ms, 125ms, 250ms, 1/2 sec, 1 sec, 2 sec (User selectable)

- VoiceTag Audio Recording (B, C & D Versions): Up to 30 seconds of audio notes with each measurement

- Integrators: Three simultaneous "virtual" noise meters. Integrator 1 is preset to Q3 for Leq functions. Integrators 2 & 3 can be configured with the following:

Exchange Rate: 3, 4 or 5 dB

Threshold: 70dB to 120dB (1 dB steps)

Time Weighting: None or Slow

Criterion Level: 70dB to 120dB (1 dB steps)

Criterion Time: 1 to 12 hours in 1 hour steps

- Integrator Quick settings:

EU, OSHA HC & OSHA NC, OSHA HC & ACGIH, 

MSHA HC & MSHA EC, Custom 1 & Custom 2

- Measurement control: Pause & Back Erase with user selectable duration

- Dimensions: 

Size: 283mm x 65mm x 30mm

Weight: 300gms/10oz

- Batteries: 4 x AA Alkaline

- Battery life: 

Typically 12 hours with Alkaline AA

Typically 20 hours with Lithium AA Non-Rechargeable

Battery life is dependent upon the battery type, quality & screen brightness

- Connections: 

USB Type B to PC

AC & DC Output via ZL:174 (2 x Phono, 1m)

Multi-pin IO for external power via ZL:171 cable (2.1mm socket)

External Power: 5v-15v via MultiIO socket via ZL:171 cable (2.1mm socket)

- Tripod Mount: 1/4" Whitworth socket

- Case: Material: High Impact ABS-PC with soft touch back & keypad

- Environmental: 

Temperature: Operating -10°C to +50°C, Storage -20°C to +60°C

Humidity: Up to 95% RH Non Condensing

- Measurement Functions: 

- Displayed Functions:

LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq

Graph of Short LAeq, LCPeak

Measurement Run Time

Integrators 2 & 3: TWA, Dose%, Est Dose%

Real-Time Octave Band Filters

NR & NC values & curves

- Stored Functions: 

LXYMax & Time History of LXYMax

LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak

Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq

Integrators 2 & 3: LAVG , TWA. %Dose 

Time History of LAVG

Octave Bands: Overall Leq & Leq Time History for each band

NR & NC values & curves

Measurement Run Time

Time & Date of Measurement Start

where x=A ,C ,Z; y= F, S, I

Other functions may calculated by the NoiseTools software and displayed on download.

Details

 Datasheet

Read more
  • 良質な取り決め
  • オリジナル保証
  • 宅配便
  • 買い取り簡単化

おまけチャンス‐ニュースを受ける登録