For full functionality of this site it is necessary to enable JavaScript.
EMIN.ASIA
0

Analysis of I-V curve deviations in solar power systems

04/17/2026 14:10:16

I-V curve analysis is an in-depth diagnostic method for identifying hardware performance issues. For accurate results, devices like the Fluke Solmetric PVA-1500 compare the measured curve to a standard curve, while automatically adjusting for actual radiation and temperature conditions.

Below is the process analysis basis, derived from the scheme processing attempt by the National Renewable Energy Laboratory (NREL).

Verify measurement data

Before troubleshooting the module, you need to ensure the test is valid:

Open circuit: If no curve is obtained, check the measurement cable connection or series fuse for a broken connection.

Discontinuous connection: If the curve drops sharply or breaks abruptly, the cause is often a misaligned measurement cable or a faulty crimped terminal. The connection should be isolated and repaired before re-measuring.

Identifying 6 types of I-V curve deviations

A normal system has an efficiency coefficient of 90% - 100%. If it is lower, compare it to the following six types of deviations:

If the result is lower, compare it to the following characteristic distortion patterns:

1. Staircase curve

The cracks appear due to uneven current flow between battery cells.

The bypass diode will activate to conduct current through the weak or shaded area of ​​the battery.

Common causes: localized shading, uneven dirt distribution, or faulty battery cells.

2. Low short-circuit current (Isc)

The curve shape remains normal, but the Isc value decreases.

Common causes: inaccurate radiation sensor readings, dirty or heavily covered battery surface.

3. Low open-circuit voltage (Voc)

This is often related to temperature deviations during the measurement process.

Since Vocs are less affected by aging, environmental conditions should be checked before concluding that the module is faulty.

4. The knee joint is rounded

This indicates a decline in performance over time.

The main cause is the aging or degradation of the module.

5. Low voltage ratio (Vmp / Voc)

The vertical section of the curve is steeper than normal.

Comparisons between strings can be used to detect faulty wires or connections.

6. Low current ratio (Imp / Isc)

The horizontal section has an unusually steep slope.

Shadow and dirt effects must be ruled out before inspecting the hardware.

Fluke device applications 

Fluke-PVA-1500HE2 this is the optimal device for current 1500V systems. In addition to providing detailed data, it also supports the storage and monitoring of long-term performance trends for the entire project.

Invitation to attend the Fluke Technical Workshop

To master the skills of using analyzers and directly practice analyzing various types of aberrations on real PV systems, we invite you to participate in Fluke's in-depth workshop: Predictive Maintenance for Solar Power Systems: Maximum Safety - Breakthrough Performance

Key content:

- Practical testing with the PVA-1500 Series instrument.

- Detailed instructions on the standard NREL troubleshooting flowchart.

👉 Link to participate: Here!

Representative products to support your work:

- PVA-1500 Series photoelectric analyzer.

- PVA-1500HE2 tool kit (including I-V monitor, clamp meter and multimeter).

Related News

How Much Power Can a Rooftop Solar System Still Generate After 5 Years?
09/26/2026 08:44:51

Sau 5 năm vận hành, hệ thống điện mặt trời áp mái có thể vẫn hoạt động ổn định nhưng sản lượng không còn giống thời điểm mới lắp đặt. Mức suy giảm phụ thuộc vào tuổi thọ tấm pin, nhiệt độ, bức xạ, độ ẩm, bụi bẩn, dây dẫn, đầu nối và bộ biến tần.

EMIN is the Official FOTRIC Distributor in Vietnam
09/25/2026 11:55:21

Since August 2020, EMIN has been an official distributor of FOTRIC products and services in Vietnam. FOTRIC specializes in thermal imaging cameras and acoustic imaging cameras for electrical inspection, industrial maintenance, leak detection, research and development, and building inspection.

EMIN is the Official JEIO TECH Distributor in Vietnam
09/25/2026 11:13:01

Since September 2018, EMIN has been an official distributor of JEIO TECH products and services in Vietnam. The company specializes in developing and manufacturing laboratory equipment, environmental testing equipment, and solutions for scientific research and industrial applications.

How Is Cargo Tank Wall Thickness Inspected?
09/25/2026 10:42:16

Non-destructive ultrasonic testing enables tank wall thickness measurements in areas prone to wear, corrosion, or high stress. This method helps assess the service condition of tanks used to transport hazardous materials or waste.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support