REX M510T(Optical DO) Multi-parameter Analyzer (20.000 pH, 2000.00 mV, 20.000) pX, 9.999e+9, 0.000 μS/cm ~ 3000 mS/cm)
Model: M510T
Parameters: pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)
pH Measurement
Range: (-2.000~20.000) pH
Resolution: 0.1 pH, 0.01 pH, 0.001 pH
Accuracy: ±0.002 pH
Calibration Points: Up to 8
Standard Customization: Yes
Calibration Reminder: Yes
Standard Recognition: USA, NIST, MERK, JIS, GB, DIN, GOST buffers
Slope Limit: Yes
mV/ORP
Range: (-2000.00~2000.00) mV
Resolution: 1 mV, 0.1 mV, 0.01 mV
Accuracy: ±0.1 mV or ±0.03%
EH ORP Mode: Yes
ORP Calibration Points: 1 custom point (relative mV)
pX
Range: (-2.000~20.000) pX
Resolution: 0.1 pX, 0.01 pX, 0.001 pX
Accuracy: ±0.002 pX
Calibration Points: Up to 8
ISE (Ion Selective Electrode)
Range: 1.000e-9 ~ 9.999e+9
Units: mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Resolution: Up to 4 significant digits
Accuracy: ±0.3%
Calibration Points: Up to 8
Conductivity
Range: 0.000 μS/cm ~ 3000 mS/cm
Resolution: 0.001 μS/cm minimum, changed with range
Accuracy: ±0.5% FS
Reference Temperature: 5 ºC, 10 ºC, 15 ºC, 18 ºC, 20 ºC, 25 ºC
Calibration Points: Up to 5
Calibration Reminder: Yes
Standard Recognition: 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm; 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm
Resistivity
Range: 5.00 Ω·cm ~ 100.0 MΩ·cm
Resolution: 0.01 Ω·cm minimum, changed with range
Accuracy: ±0.5% FS
TDS
Range: 0.000 ppm ~ 1000 ppt
Resolution: 0.001 ppm minimum, changed with range
Accuracy: ±0.5% FS
Salinity
Range: (0.0~80.0) ppt
Resolution: 0.1 ppt
Accuracy: ±1 ppt
Dissolved Oxygen (Optional fluorescent DO electrode)
Sensor Type: DO-968-HC Optical DO electrode
Range: (0.00~20.00) ppm
Resolution: 0.01 ppm
Repeatability: 0.15 ppm
Accuracy at 0% DO: ≤0.1 ppm
Measurement Accuracy: ±0.30 ppm
Response time: ≤45s (90% response at 20 °C)
Salinity Compensation Accuracy: ±2%
Calibration Reminder: Yes
Calibration Points: Air-saturated water or zero point
Barometric Compensation: Yes
Manual Salinity Factor Correction: Yes
Saturation (Optional fluorescent DO electrode)
Range: (0.0~200.0)%
Resolution: 0.1%
Measurement Accuracy: ±10.0%
Dissolved Oxygen Concentration (Polarographic)
Sensor Type: DO-958-Q polarographic DO electrode
Range: (0.00~99.99) ppm
Resolution: 0.01 ppm
Accuracy:
±0.10 ppm, (0.00~50.00) ppm
±0.50 ppm, (50.0~99.99) ppm
Calibration Reminder: Yes
Calibration Points: Air-saturated water or zero point
Barometric Compensation: Yes
Manual Salinity Factor Correction: Yes
Saturation (Polarographic)
Range: (0.0~600.0)%
Resolution: 0.10%
Accuracy: ±2.0%
Temperature
Range: (-10.0~135.0) ºC, (14.0~275.0) ºF
Unit: ºC, ºF
Resolution: 0.1 ºC, 0.1 ºF
Accuracy: ±0.1 ºC
Measurement
Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts: Reading, Stable, Locked
Temp. Compensation: ATC, MTC
Data management
Data Storage: 1000 Groups
GLP Features: Yes
Inputs
pH Electrode: BNC (Q9)
DO with Temp. Probe: 4-pin aviation connector
Conductivity with Temp. Probe: 5-pin aviation connector
Outputs
USB: USB 2.0 flash drive, PC, Bluetooth Printer
Display options
Backlight: Yes
Auto Shutdown: 300, 600, 1200, 1800, 3600 sec., off
IP Rating: IP67
Date and Time: Yes
General
Power: Rechargeable Lithium battery, AC Adapter (Input: 100-240V AC; Output: 5V DC, 2A)
Dimensions: 90×255×40 mm
Net Weight: 500 g
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts