Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Detector: RAP-RS2 Probe – External Probe Halogen-quenched, uncompensated GM tube with thin mica window, 1.4-2.0 mg/cm2 areal density. Effective diameter of window is 45 mm (1.75 in.).
Operating Range
mR/hr – .001 (1µR) to 100
CPM – 0 to 350,000
µSv/hr – .01 to 1000
CPS – 0 to 5000
Total Counts- 1 to 9,999,000 counts
Energy Sensitivity: Detects Alpha down to 2 MeV. Detects Beta down to .16 MeV; typical detection efficiency at 1 MeV is approx. 25%. Detects Gamma down to 10 KeV through the detector window. 3340 CPM/mR/hr (137Cs). Smallest detectable level for 125I is .02 µCi at contact.
Built-In Efficiencies: Sulfur (35S), Strontium (90Sr/y), Cesium (137Cs), Phosphorus (32P), Carbon (14C), Iodine (131I), Cobalt (60Co), and Alpha
Accuracy
Reference to Cs137
Typically ±15% from factory, ±10% with NIST Source Calibration
Selectable Alert Settings: mR/hr .001 – 100 and CPM 1 – 350,000. 70db @ 1m. Pulsating beeper sounds the alert. Adjustable alert levels are used for mR/hr / CPM, and µSv/hr / CPS. Alarm will sound when in Timer Mode when set alarm threshold is reached.
Anti-Saturation: Meter will hold at OVER RANGE in fields as high as 100 times the maximum reading.
Averaging Periods: This Radiation detector display updates every 3 seconds. At low background levels, the update is the average for the past 30-second time period. The timed period for the average decreases as the radiation level increases.
Display: Graphic LCD with Backlight
Outputs: USB for use with Free Observer USB Software for PCsBluetooth Option: Wirelessly connects the instrument with an Android mobile device for use with Free Observer BLE App
Count Light: Red LED flashes with each radiation event.
Audio Indicator: Internally mounted beeper (can be switched off for silent operation)
Power Requirements: USB Power or Two (2) AA alkaline batteries (included). Approx. 800 hrs @ background.
Temperature Range: -10° to +50°C (14° to 122°F)
Humidity: 10% to 70% Non-Condensing.
Size
140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.)
Probe: 260 X 70 X 25 mm (10.25 X 2.75 X 1 in.)
Weight: 570 g (1.25 lbs.)
Includes: RAP-RS2 External GM Probe, 3 ft BNC Cable, Carrying Case, Xtreme Boot, Lanyard, Stand, Batteries, Mini-USB Cable, Observer USB Software, Observer BLE App, Certificate of Conformance
Options
NIST Calibration, Radiation Response Kit
Bluetooth module available for use with Obsever BLE software and Rad Responder