Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Inputs
Microphone
MC800: Free field ½”, 50 mV/Pa sensitivity; 0 V; IEC 61094-4 WS2F, 3.15 Hz-20 KHz.
MP800: preamplifier, automatic detection of model and calibration data. SDI (Sensor Digital Interface). CTC automatic electric calibration
Accelerometer IEPE, 4-pin circular push-pull, tri-axial
Measuring ranges(with MC800 microphone, MP800 preamplifier):
Dynamic range > 125 dB
Linear Operating Range
A (1kHz) 20 dB – 137 (140 pk)
C 22 dB – 137 (140pk)
Z 25 dB – 137 (140 pk)
Frequency weightings: A, C + B or Z (user selection). 3 simultaneous
Averaging: Linear, exponential, moving, max, min
Spectral Analysis
Octave: Real time, 1/1 octave, 8 Hz to 16 kHz, IEC 61260-1:2014
Real time, 1/3 octave 6.3 Hz to 20 kHz, IEC 61260-1:2014
FFT: Real time FFT in parallel with 1/3 oct. (specifications TBA)
Reverberation time: T60 calculation
Noise Criteria: NC, NR, RNC, RC
Intelligibility: STI/STIPA
Statistical Analysis; Broad band and Spectral: 7xLn (Lin and Mov) selectable percentile levels (0.1%-99.9%). Probability/Cumulative distribution.
Audio
Recording:
Mode: continuous, manual or event triggered. Resolution 16, 24, 32-bit.
Audio-band: 10, 20 KHz. Format: Wave or compressed (ADPCM)
Playback: Embedded codec for signal generation. Playback channels: Generator, Trace (.wav) or Measurement (Mic input). Playback Mic or Mic-filtered (Wide Band A, C, Aux or 1/3 band selectable) for Audio playback of microphone input.
Measurement Control: Start, stop, pause, reset, back-erase, continue, event marking, manual audio recording.
Calibration: Acoustic: Manual or automatic (tone detection). Calibrations history: date/time, dB correction. Free Field, Random Incidence, environmental and shield corrections
Vibration Measurements: Triaxial vibration
Human exposure to hand-transmitted vibration (ISO 5349)
Human exposure to whole-body vibration (ISO 2631-1)
Human exposure to whole-body vibration in buildings (ISO 2631-2)
Triggers:
Broad band: Single or multiple (OR/AND) on broad-band levels, levels difference, Ln, Lmov
Spectra: On 1/1 or 1/3 oct. masks. Single - All bands mode. Max, min thresholds editable (man or json file)
Detectors
Tonality: Automatic identification according to DM 16/03/1998 and ISO1996-2
Impulsivity: Automatic identification according to DM 16/03/1998
Storage
Physical: Embedded 4GB eMMC and up to 64GB µSD (TBA); USB memory stick.
Cloud: Upload to cloud storage service (NS-Storage). Manual or automatic (Push)
Archive: List, preview and plot with zoom function of stored data. Manual data upload on NS-Storage cloud
Datalogging
Time history: independent Short, Standard, Report steps.
Short: 10 ms. Standard: 100/200/500 ms / 1 s.
Reports: 10/20/30 s,1/2/5/10/20/30/60 m
Events: triggered broad-band, octave, Ln values