GOTT GOTT-EPT-146 电气保护培训套件
制造商: GOTT Model: GOTT-EPT-146 P/N: 146-000 来源: Malaysia 保障: 12 Month - 报价要求
- 联系
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222)730.39.68
HCM city: (028) 38.119.636
Modules:
- Transformer And Service Line Connection - Code 146-002
Adjustable three phase transformer ratio : 240/240 VAC 0.2A, 240/240VAC 5A
Input voltage : 380/220Vac
Output socket voltage : L1, L2, L3, N, PE
Pilot lamp: L1, L2, L3
Protection: MCB 3P 10A 6kA
- Circuit Breaker 4 Pole (Ac/Dc) - Code 146-007
Input voltage socket: L1, L2, L3, N, PE
Output voltage socket: L1, L2, L3, N, PE
Protection: ELCB 4P 25A iF 30mA (AC/DC)
- Over Under Voltage Relay - Code 146-029
Operating voltage: 415VAC
Supply variation: 0.75~1.25 x Un
Upper trip: 1.05~1.25 x Un
Lower trip: 0.75~0.95 x Un
Time Delay: 0.2 ~10 sec
- Over Under Current Relay - Code 146-030
Input voltage: 415/240 VAC
Output voltage: 415/240 VAC
Protection: Fuse 0.2A, 5A
Operating voltage: 415/240VAC
Supply variation: 85~115% of Un
Time delay (t) (from fault): 0.1 to 3 sec.
On delay (ton): 0.1 to 10 sec.
Reset time: 200ms
- Power Supply Unit - Code 146-001
Input voltage: 415/240 VAC
Output voltage: 415/240 VAC
Protection: Fuse 0.2A, 5A
- Three Phase Main Supply Unit 415vac – Code 146-031
Input voltage: 3phase 415VAC
Output voltage: 3 phase 415VAC
Protection: 20A MCB Ampere Trip
- Circuit Breaker 3 Pole 6A - Code 146-003
Input voltage socket: L1, L2, L3, N, PE
Output voltage socket: L1, L2, L3, N, PE
Protection: MCB 3P 10A 6kA
- Modular Fuse Switch - Code 146-005
Input voltage socket: L1, L2, L3, N, PE
Output voltage socket: L1, L2, L3, N, PE
Protection: Modular fuse 32A
- Fi Circuit Breaker 2 Pole Ac - Code 146-006
Input voltage socket: L, N, PE
Output voltage socket: L, N, PE
Protection: ELCB 2P 25A iF 30mA
- Transformer 220V/0-24-42-240 VAC 1A
Input voltage : 240 VAC
Output voltage : 240V, 42V , 24V 1A
Protection : MCB 1P 0.5A 6kA
- Circuit Breaker 1 Pole - Code 146-004
Input voltage socket: L, N, PE
Output voltage socket: L, N, PE
Protection: MCB 1P 10A 6kA
- Protective Earthing Socket - Code 146-010
Input voltage socket: L1, L2, L3, N,
PE Output voltage socket: L1, L2, L3, N, PE
- Insulation Tester - Code 146-009
Input voltage : 240 VAC
Display: LED Test, Reset
- Load With Fault To Frame - Code 146-011
Input voltage socket: L, N, PE
- System Earth - Code 146-013
Earth resistance : 2Ω, 8Ω
- Contact Resistance - Code 146-015
Earth resistance : 10Ω, 470Ω, 15kΩ
- Load Extra-Low Voltage 24 Vac - Code 146-012
Input voltage: 24VAC
- Protective Earth - Code 146-014
Earth resistance : 1.5Ω, 220Ω, 470Ω, 820Ω, 1322Ω, 5kΩ
- Capacitance System - Code 146-019
Capacitance : 0.1uF/450V, 0.01uF/630V
- Insulation Resistance - Code 146-020
Insulation resistance : 15kΩ, 47kΩ, 82kΩ, 220kΩ
- Conductive Parts With Potential - Code 146-016
Conductive resistance : 1.5Ω, 10Ω
- Course Of The Earth Voltage - Code 146-017
Electric potential level : 1m.,2m., 3m., 5m., 7.5m., 10m., 20m.
- Flood Detector - Code 146-021
Level simulate: 2 Level
Relay coil: 240 VAC
- Load Floor Lamp 240 Vac - Code 146-023
Input voltage : 240 VAC
Lamp type: Incandescent
- Isolating Transformer 240/240 Vac 1a - Code 146-025
Input voltage: 240 VAC
Output voltage: 240VAC/ 1A
Voltage Ratio: 1 : 1
- Auto Transformer 0-42-240 Vac 1 A - Code 146-026
Input voltage: 240 VAC
Output voltage: 42 VAC 1A
Protection: MCB 1P 0.5A 6kA
- Extra-Low Voltage Transformer - Code 146-027
Operating voltage: 240 VAC Supply
variation: 210~240 VAC
- Phase Voltage Relay - Code 146-028
Loop resistance : 220Ω, 4.7kΩ
- Short-Circuit Current & Loop Resistance - Code 146-018
- Load With Diode - Code 146-022
Resistance: 100Ω, (series with diode)
- Ac Voltmeter - Code 162-011
Measurement Mode: AC
Voltage Ranges: 5V, 50V, 250V, 1000V
- Ac Ammeter - Code 162-012
Measurement Mode: AC
Current Ranges: 1A, 5A, 25A
- U-Link - Code 159-019
For connecting junction point
- Safety Connecting Lead - Code 237-001
4mm connecting leads
- Vertical Frame - Code 297-000
High level : DIN standard A4 with two shelves
Material: Aluminium
Side Frame: T shape
Size: 3-Layer 1450mm Length
- Experiment Manual - Code 146-035
Experiment Topics:
• Understanding the Function of Over/Under Voltage Relay
o Under Voltage Protection
o Over Voltage Protection
• Protection for Over and Under current Circumstances
o Under Current Protection o Over Current Protection
• Protection from Unbalance Phase Situations
o Wrong Phase Sequence Detection
o Unbalance Voltage Detection
• The Usage of Two Level Liquid Detector Relay
• Insulation Testing for Electrical Safety
• Usage of Isolation Transformer to Prevent Electric Shock
• Protection from Pulsating DC Leakage Current
• Fault Current Protection by Using RCCB
• Course of Earth Voltage Due to Ground Rods
Manuals :
(1) All manuals are written in English
(2) Model Answer
(3) Teaching Manuals
Datasheet
This Electrical Protection Trainer have been created for learning of Dangers caused of
touch of the electrical or electrical conductor equipment, Leakage current, Simulation of
protection of leakage current by using FI circuit breaker, Prevention of “Fault” by using
separation transformer. It’s designed as panel system with 2 level mounting frame.
There have clearly symbol on each panel by silk screen. All of connecting point via safety
connector for safety in operation.