Width: 5.18 in
Height: 2.7 in
Length: 6.9 in
Weight: 370 g
Accuracy: ± 0.01 %
Channels: One channel standard, second channel optional
Mounting: Panel
Materials: Manganese-Nickel
Input Type: Strain
Resolution: 16-bit A/D
Form factor: 1/8 DIN
Runout Mode: Updated at rate selected by digital filter. Runout is normally stored in memory and recalled via front-panel switch, over the serial interface, or by selecting runout display mode on rear connector.
Display Note: -32768 to 32767 with programmable decimal points; 14 mm (0.56") red LED
Display Type: LED
Reading Rate: Limited to 1000/s divided by number of channels
Accuracy Note: ± 0.01% of reading ± 1 count of A/D @ 25°C (77°F)
Output Detail: Analog Output: 0 to 5 Vdc; tracks display reading; voltage outputs will sink or source 1 mA; 300V isolation between analog outputs and instrument ground
Output Method: RJ11 jack for serial interface
Output Signal: Voltage
Remote Inputs: Display Peak, Display Runout, Reading, Reset Peak, Runout Reading, Tare
Sampling Rate: 1000 Hz
Control Output: N/A
Data Interface: N/A
Digital Filter: Programmable Cutoff Frequency
Peak Detection: Updated at rate selected by digital filter, peak stored in memoryrogrammed to give limit #1 output up to 100 seconds after a programmed limit is reached. This output can be used to reset the peak reading by tying limit #1 output to remote input
Rollover Error: ± 2 counts of A/D @ 25°C (77°F)
Supply Voltage: 115 Vac
supply-voltage: 115 Vac
Range Selection: Selectable by dip switch on rear of unit
Calibration Note: Shunt calibration capability with span programmable from front panel; no potentiometer adjustments; access code prevents unauthorized calibration switches
Measurement Type: Current, Strain, Voltage
Number of Digits: 5
Number of Inputs: 1
SetPoint Outputs: 4 isolated open collector transistor outputs rated 30 Vdc maximum; will sink up to 50 mA; 300 V isolation between limit outputs and system ground; limit #1 can be programmed to be delayed from 1 to 100 seconds
Bridge Resistance: 100 to 5000 Ω
Cutout Dimensions: 2.45 x 5.06 in
Electrical Output: 0 to 5 Vdc
Power Consumption: 8 W
Sensor Excitation: ± 15 Vdc, ± 5 Vdc @ ± 50 mA
Supply Power Type: AC
Convert/Hold Input: Normally high; if pulled low, holds display
Input Bias Current: ± 50 nA maximum ± 100 pA/°C (per input channel)
Coarse Gain Setting: Selectable by rear switches
Input Analog Filter: 4-pole active anti-alias; 500 Hz cutoff on single-channel unit and 250 Hz cutoff on dual-channel unit
Input Configuration: Front Keypad
Internal Resolution: 16 bit
Settable Parameters: Digital Filter, Limits, Offset, Span
Range Selection Note: 5.1, 10.2, 15.3, 20.0, 26.3, 30.6, 35.1, 39.2 (in mV)
Electrical Connection: Screw Terminal
Bridge Resistance Note: 100 to 5000 Ω; 4-wire or 6-wire configuration
Operating Temperature, Max: 60 °C
Operating Temperature, Min: -20 °C