Pulsar measurement IMP+ I.S. ATEX液位传感器

Dimensions: 186 mm (H) x 133 mm (D) (7.3 in (H) x 5.2 in (D))

Cable Entry: 2 off cable glands 4.5 mm to 10 mm (0.2 in to 0.4 in); Torque to 2 NM

Mounting: 

IMP3 - 3 m (9.8 ft) version: 1.5 in BSP/NPT

IMP6 - 6 m (19.7 ft) version: 1.5 in BSP/NPT

IMP10 - 10 m (32.8 ft) version: 2 in BSP/NPT

Suits BSP & NPT, parallel and tapered

Weight Nominal: 1kg (2.2 lb)

Enclosure Protection: IP67

Temperature (Process): -40°C to +65 °C (-40 °F to +149 °F )

Temperature (Ambient): -40 °C to +80 °C (-40 °F to +176 °F)

Input Voltage Range: 11-30 V, 3.5-22mA

Accuracy: ±0.25% or 6 mm (0.2 in) whichever is greater

Resolution: ±0.1% or 2 mm (0.1 in) whichever is greater

4-20mA Outputs: Resolution 5 μA; both active and passive outputs

Temperature Compensation: Via internal temperature sensor 0.5 °C (± 32.9 °F) accuracy. Level and volume conversion are installed allowing linearisation for tank shapes.

PC Interface: All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on-screen.