- Number of channels: 3
Measured parameters: V, Vpk, I, Ipk, Is, W, VA, VAR, PF, CFi, F, THD V, THD I, E.
Voltage
- Measurement range: 15V / 30V / 60V / 150V / 300V / 600Vrms (CF=2), 6 ranges, HV option up to 1800Vrms
- Accuracy:
+ DC, 10Hz to 1kHz: 0.1% RD + 0.08% RNG
+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.08% RNG
- Harmonic accuracy:
+ DC, 10Hz to 1kHz: 0.1% RD + 0.08% RNG
+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.08% RNG
- Input impedance: 4MΩ
AC/DC Current
- Measurement range: 5mA / 20mA / 50mA / 200mA / 500mA / 2A / 5A / 20Arms (CF=4)
- Accuracy:
+ DC, 10Hz to 1kHz: 0.1% RD + 0.1% RNG
+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.1% RNG
- Harmonic accuracy:
+ 10Hz to 1kHz: 0.1% RD + 0.1% RNG
+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.1% RNG
- DC current accuracy: 0.1% RD + 0.1% RNG
Power
- Measurement range: 75mW ~ 12kW (48 ranges)
- Accuracy:
+ 47Hz to 63Hz: 0.1% RD + 0.1% RNG
+ 1kHz to 10kHz: (0.1 + 0.1 × kHz)% RD + 0.18% RNG
- Power factor accuracy: 0.001 + (15ppm / PF) × Hz
Frequency
- Measurement range: DC, 10Hz ~ 10kHz
- Accuracy: 0.06% RD
- Reference source: Voltage source
Other
- Display resolution: 5 digits
- Display update rate: 0.25 sec / 0.5 sec / 1 sec / 2 sec
- Power supply: 100~240V ±10%, 50/60Hz
- Communication: GPIB + USB or CAN + USB
- Operating temperature: 0˚C ~ 40˚C
- Storage temperature: -40˚C ~ 85˚C
- Safety & EMC: CE (including EMC & LVD)
- Dimensions (H × W × D): 133 × 212 × 420 mm
- Weight: approx. 7.5 kg