Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Rated output voltage: 80 V
Rated output current: 510 A
Rated output power: 15000 W
Output power ratio: 2.72
Constant Voltage Mode
Line regulation [0.01 % of Vo_rated]: 8 mV
Load regulation [0.02 % of Vo_rated]: 16 mV
Ripple and noise (p-p): 200 mV
Ripple and noise (r.m.s.): 16 mV
Temperature coefficient: 100 ppm/°C from rated output voltage, following 30 minutes warm-up.
Remote sense compensation voltage (5 % of Vo_rated): 4 V
Rise time (Rated load): 30 ms
Rise time (No load): 30 ms
Fall time (Rated load): 80 ms
Fall time (No load): 1000 ms
Transient response time: 1.5 ms
Constant Current Mode
Line regulation [0.05 % of Io_rated]: 255 mA
Load regulation [0.1 % of Io_rated]: 510 mA
Ripple and noise (r.m.s.): 510 mA
Temperature coefficient: 100 ppm/°C from rated output current, following 30 minutes warm-up.
Protection Function
Over voltage protection (OVP) - Setting range: 5.00 V to 88.00 V
Over voltage protection (OVP) - Setting accuracy: 80 mV
Over current protection (OCP) - Setting range: 5.00 A to 561.00 A
Over current protection (OCP) - Setting accuracy: 1020 mA
Overpower protection (OPP) - Setting range: 300 W to 16500 W
Overpower protection (OPP) - Setting accuracy: 150 W
Over voltage limit (OVL) - Setting range: 0.00 V to 84.00 V
Under voltage limit (UVL) - Setting range: 0.00 V to 84.00 V
Over current limit (OCL) - Setting range: 0.00 A to 535.50 A
Under current limit (UCL) - Setting range: 0.00 A to 535.50 A